Air is drawn in continuously by the circulation system. During pumping, spraying and return, the fluid keeps contacting air. A large return drop, air suction in pipework or strong agitation easily creates new bubbles. This relates to defoamer choice but cannot be left entirely to the defoamer; if a lot of air keeps entering, foam may re-form during operation even after it subsides.
The defoamer does not match the formulation. Cutting fluid may contain surfactants, lubricating components, rust-inhibiting components and other functional additives that influence each other and change the stability of the bubble film. A defoamer needs suitable dispersion in the system and must reach the foam film to work. With poor compatibility there may be slow defoaming, short foam suppression or even local separation. When changing defoamers, compare more than single-time defoaming speed; look at dispersion in the real fluid and performance after circulation.
The fluid is contaminated by impurities. After long use, hydraulic oil, lubricating oil, cleaning-agent residue and metal fines may enter. These foreign components can change the interfacial state, making foam easier to form or harder to break. If a fluid ran normally and obvious foam appears only after some time, check for tramp oil, improper top-up or insufficient maintenance rather than concluding the defoamer failed.
The defoamer is added in an unsuitable way. More is not better. Adding too much at once, or without sufficient dispersion, can cause locally high concentration and a change in system compatibility. A defoamer that performs well when static does not necessarily hold up under continuous circulation, spraying and high shear, so evaluate it under real operating conditions, not just the short-term change after dosing.